What to do if Upright Freezer can't be cooled

×

Take a look at the thermostat from Upright Freezer. The freezer temperature regulator is installed in the Upright Freezer, and the temperature does not reach the temperature required by the temperature regulator. If the compressor does not shut down day and night, the freezer will cause the extreme refrigerant temperature of the refrigerant. Most of this phenomenon occurs in air-cooled refrigerator compartment refrigerators. Because the evaporator defroster of the refrigerator compartment is broken, the ice is blocked. The cooling fan is broken, or there are too many things in the freezer, the outlet is blocked, and the reason for the poor cooling effect cannot be ruled out.

You can verify whether the power connection is correct, check whether the lights in the freezer are normal, or you can further test with an electric pen. If the power connection is normal, you can monitor whether the compressor is working properly. The compressor makes a slight motor vibration during normal operation. The high-pressure output buffer pipe in the compressor is damaged or the screw fixing this pipe is loose. The high-pressure pipe does not discharge air, and the low-pressure pipe does not suck air. Therefore, the compressor works but cannot be cooled.

The compressor is working normally, you can check whether the refrigerant is used up in the cooling system. After the freezer runs for about 3-5 minutes, the power supply can be cut off and you can hear the sound of water flow. If there is no sound. Indicates that the refrigerant in the refrigeration system is exhausted or leaking. The compressor may lose its working capacity.

Solution: If there is a system leak, usually find the leaking part of the system, weld, pressure test, and add the refrigerant to a certain amount within an appropriate time to make the evaporator frost or the freezer to reach the rated temperature.

prev
Understanding the performance of commercial display freezer
The main situations where the temperature of the Upright Freezer does not drop
next
recommended for you
no data
Get in touch with us
Apex Refrigeration Equipment Limited was founded in 2007 as a professional manufacturer of commercial refrigeration equipment. 
Contact Us

Contact person: Eric Zhang

Tel: 0757-81781221

Email: info@apexcool.com

WhatsApp: +86 13760614505

Address: Room 601, Building 1, Honghui City Garden, Guicheng, Foshan, Guangdong, China

Copyright © 2024 Apex | Sitemap
Customer service
detect